<ArticleTitle>Effects of Millimetric Shifts in Breast Cancer Radiotherapy on the Radiation Dose Distribution</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>1197</FirstPage>
			<LastPage>1199</LastPage>
			<ELocationID EIdType="pii">32220</ELocationID>
			
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Yusuf Tolga</FirstName>
					<LastName>Sanli</LastName>
<Affiliation>Radiation Oncology,Hatay Public Hospital, Hatay, Turkey</Affiliation>

</Author>
<Author>
					<FirstName>Funda </FirstName>
					<LastName>Cukurcayir</LastName>
<Affiliation></Affiliation>

</Author>
<Author>
					<FirstName>Fatma </FirstName>
					<LastName>Abacigil</LastName>
<Affiliation></Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>1970</Year>
					<Month>01</Month>
					<Day>01</Day>
				</PubDate>
			</History>
		<Abstract>Background: This study aimed to facilitate decision-making in cases of breast cancer radiotherapy shifts by simulating millimetric shifts and analyzing their effects on dose distribution. Methods: The study included 30 patients with left side breast cancer who were treated with three dimensional conformal radiotherapy (3D-CRT) in the Radiation Oncology Department in Hatay Public Hospital, between January 2013 and April 2015. A treatment plan shifting at three axes with six different measures was simulated. Results: The biggest difference in values was (3mm shift) 476cGy, with a 7.7 % change for heart and 25.6% for spinal cord. The shifts in values respectively for CTV min, mean, max were -4.8%, 2.5%, 4%. The differences for lymphatic min, mean, max were 21.3%, 20.3%, -12.2%. Conclusion: The most important thing is not the treatment plan quality, but its practicality. The treatment plan must be practical and its practice must be controlled rigidly.</Abstract>