<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>West Asia Organization for Cancer Prevention (WAOCP), APOCP's West Asia Chapter.</PublisherName>
				<JournalTitle>Asian Pacific Journal of Cancer Prevention</JournalTitle>
				<Issn>1513-7368</Issn>
				<Volume>20</Volume>
				<Issue>2</Issue>
				<PubDate PubStatus="epublish">
					<Year>2019</Year>
					<Month>02</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Radiologists’ Performance at Reduced Recall Rates in Mammography: A Laboratory Study</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>537</FirstPage>
			<LastPage>543</LastPage>
			<ELocationID EIdType="pii">82232</ELocationID>
			
<ELocationID EIdType="doi">10.31557/APJCP.2019.20.2.537</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Norhashimah </FirstName>
					<LastName>Mohd Norsuddin</LastName>

						<AffiliationInfo>
						<Affiliation>Medical Image Optimisation and Perception Group (MIOPeG), Discipline of Medical Radiation Sciences, Faculty of
Health Sciences, The University of Sydney, Lidcombe NSW, Australia.</Affiliation>
						</AffiliationInfo>

						<AffiliationInfo>
						<Affiliation>Diagnostic Imaging and Radiotherapy Programme,
Faculty of Health Sciences, The National University of Malaysia (UKM), Kuala Lumpur, Malaysia.</Affiliation>
						</AffiliationInfo>
<Identifier Source="ORCID">0000-0003-3877-1292</Identifier>

</Author>
<Author>
					<FirstName>Claudia </FirstName>
					<LastName>Mello-Thoms</LastName>
<Affiliation>Medical Image Optimisation and Perception Group (MIOPeG), Discipline of Medical Radiation Sciences, Faculty of
Health Sciences, The University of Sydney, Lidcombe NSW, Australia.</Affiliation>

</Author>
<Author>
					<FirstName>Warren </FirstName>
					<LastName>Reed</LastName>
<Affiliation>Medical Image Optimisation and Perception Group (MIOPeG), Discipline of Medical Radiation Sciences, Faculty of
Health Sciences, The University of Sydney, Lidcombe NSW, Australia.</Affiliation>

</Author>
<Author>
					<FirstName>Sarah </FirstName>
					<LastName>Lewis</LastName>
<Affiliation>Medical Image Optimisation and Perception Group (MIOPeG), Discipline of Medical Radiation Sciences, Faculty of
Health Sciences, The University of Sydney, Lidcombe NSW, Australia.</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2018</Year>
					<Month>07</Month>
					<Day>10</Day>
				</PubDate>
			</History>
		<Abstract>Rationale and objectives: Target recall rates are often used as a performance indicator in mammography screening&lt;br /&gt;programs with the intention of reducing false positive decisions, over diagnosis and anxiety for participants. However,&lt;br /&gt;the relationship between target recall rates and cancer detection is unclear, especially when readers are directed to&lt;br /&gt;adhere to a predetermined rate. The purpose of this study was to explore the effect of setting different recall rates on&lt;br /&gt;radiologist’s performance. Materials and Methods: Institutional ethics approval was granted and informed consent&lt;br /&gt;was obtained from each participating radiologist. Five experienced breast imaging radiologists read a single test set&lt;br /&gt;of 200 mammographic cases (20 abnormal and 180 normal). The radiologists were asked to identify each case that&lt;br /&gt;they required to be recalled in three different recall conditions; free recall, 15% and 10% and mark the location of any&lt;br /&gt;suspicious lesions. Results: Wide variability in recall rates was observed when reading at free recall, ranging from&lt;br /&gt;18.5% to 34.0%. Readers demonstrated significantly reduced performance when reading at prescribed recall rates,&lt;br /&gt;with lower sensitivity (H=12.891, P=0.002), case location sensitivity (H=12.512, P=0.002) and ROC AUC (H=11.601,&lt;br /&gt;P=0.003) albeit with an increased specificity (H=12.704, P=0.002). However, no significant changes were evident in&lt;br /&gt;lesion location sensitivity (H=1.982, P=0.371) and JAFROC FOM (H=1.820, P=0.403). Conclusion: In this laboratory&lt;br /&gt;study, reducing the number of recalled cases to 10% significantly reduced radiologists’ performance with lower detection&lt;br /&gt;sensitivity, although a significant improvement in specificity was observed.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Recall rates</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Sensitivity</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Specificity</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">reader’s performance</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">screening mammography</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://journal.waocp.org/article_82232_cfa3a6179eb2434699aa9c405880ff8a.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
