<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>West Asia Organization for Cancer Prevention (WAOCP), APOCP's West Asia Chapter.</PublisherName>
				<JournalTitle>Asian Pacific Journal of Cancer Prevention</JournalTitle>
				<Issn>1513-7368</Issn>
				<Volume>25</Volume>
				<Issue>4</Issue>
				<PubDate PubStatus="epublish">
					<Year>2024</Year>
					<Month>04</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Comparison between Volumetric Modulated arc Therapy based Coplanar and Noncoplanar Planning for Stereotactic Body Radiation Therapy of Liver</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>1383</FirstPage>
			<LastPage>1390</LastPage>
			<ELocationID EIdType="pii">91109</ELocationID>
			
<ELocationID EIdType="doi">10.31557/APJCP.2024.25.4.1383</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Anjum </FirstName>
					<LastName>Nisha</LastName>
<Affiliation>Department of Radiotherapy and Oncology, Medical Radiation Physics Program, Manipal College of Health Professions(MCHP),
Manipal Academy of Higher Education(MAHE), Manipal, Karnataka, India.</Affiliation>
<Identifier Source="ORCID">0009-0007-2070-0775</Identifier>

</Author>
<Author>
					<FirstName>Shambhavi </FirstName>
					<LastName>C</LastName>
<Affiliation>Department of Radiotherapy and Oncology, Medical Radiation Physics Program, Manipal College of Health Professions(MCHP),
Manipal Academy of Higher Education(MAHE), Manipal, Karnataka, India.</Affiliation>
<Identifier Source="ORCID">0000-0001-8862-4552</Identifier>

</Author>
<Author>
					<FirstName>Jyothi </FirstName>
					<LastName>Nagesh</LastName>
<Affiliation>Radiotherapy and Oncology, Senior Grade
Lecturer, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, India.</Affiliation>
<Identifier Source="ORCID">0000-0003-4308-8404</Identifier>

</Author>
<Author>
					<FirstName>Sarath S</FirstName>
					<LastName>Nair</LastName>
<Affiliation>Radiotherapy and Oncology, Senior Grade
Lecturer, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, India.</Affiliation>
<Identifier Source="ORCID">0000-0002-0012-6020</Identifier>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2023</Year>
					<Month>12</Month>
					<Day>12</Day>
				</PubDate>
			</History>
		<Abstract>Background: The study aims to investigate potential dosimetric benefits between non-coplanar and coplanar beam arrangements of Volumetric-Modulated Arc Therapy (VMAT) plans for liver stereotactic body radiotherapy (SBRT). Methods: Thirteen patients who had undergone liver SBRT treatment in our department were chosen retrospectively for the study. Two sets of SBRT-VMAT plans namely, non-coplanar (NC-VMAT) and Coplanar (C-VMAT) were generated in Monaco(v5.11) planning system for Elekta Versa HD Linac using unflatten 6MV photon. The NC-VMAT plans were created by two/three non-coplanar partial arcs with couch rotation of ±150 and had an arc span of 1300 to 1600 whereas the C-VMAT plans consisted of a full arc. Both plans were compared by statistically analyzing various dosimetric and technical parameters. Results: There is no statistically significant difference observed between the C-VMAT and NC-VMAT plans for planning target volume (PTV) coverage. However, the spine dose (D1cc) was much less in the NC-VMAT plan compared to the C-VMAT plan, with mean values of 6.127 ± 3.08Gy and 9.058 ± 4.76Gy, respectively (p-value=0.002). The low dose spillage to the healthy tissue was compared by the volume receiving 5Gy (V5Gy) and 10Gy (V10Gy). V5Gy of the NC-VMAT plan was 2399.23±1870.76cc while that of C-VMAT plans was 2835.36±1930.20cc with the p-value &lt;0.001. Moreover, the monitor units(MU) were less with NC-VMAT than with C-VMAT SBRT plans (p=0.015). Conclusion: The plan quality of NC-VMAT plans was favorable compared to C-VMAT plans for liver SBRT especially in reducing spine dose, low dose spillage to healthy tissue, and MU. </Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">SBRT</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Liver cancer</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">non-coplanar VMAT</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">coplanar VMAT</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://journal.waocp.org/article_91109_87b4daa751ba930e72e4a54a0ced3364.pdf</ArchiveCopySource>
</Article>
</ArticleSet>
